大東保險絲 ( Daito Fuse)

Alarm Fuse and Fuse Holder

MP/SDP   EP

Photo
Series
Type
Rated
Voltage
Rated
Current
Breaking
Capacity
Approvals
Catalog
MP MP

AC/DC125V 0.32A - 7.5A AC/DC125V 100A






PDF
SMP SDP

(Time-lag)


AC/DC125V 1A - 7.5A AC125V 100A

DC125V 50A





PDF
EP EP

AC/DC125V 8A - 20A AC/DC125V 200A
PDF

 

Photo
Series
Type
Rated
Voltage
Rated
Current
Withstand
Voltage
Resisitance
Catalog
SMP

MPH

AC/DC125V 7.5A

Alarm Contact:

AC 750V 1min.


Other: 

AC 1500V 1min


Insultlation:

Max. 100M Ohm


Contact: 

Max. 5m Ohm



PDF
EP

EPH

AC/DC125V 20A

Alarm Contact:

AC 1250~3750V 1min.


 Other: 

AC 2500V 1min

 

Insultlation:

Max. 100M Ohm


Contact: 

Max. 5m Ohm



PDF

  

HP    GP

Photo
Series
Type
Rated
Voltage
Rated
Current
Breaking
Capacity
Approvals
Catalog
GP GP

AC/DC250V 0.32A - 5A AC/DC250V 1500A

AC125V 10000A






PDF
7.5A - 15A AC/DC250V 750A

AC125V 10000A
HP HP

AC/DC250V 0.32A - 5A AC/DC250V 1500A

AC125V 10000A
 

PDF
6.3A AC/DC250V 200A

AC125V 10000A

  

Photo
Series
Type
Rated
Voltage
Rated
Current
Withstand
Voltage
Resisitance Catalog
GPH

GPH

AC/DC125V 7.5A

Alarm Contact:

AC 750V 1min.


Other: 

AC 1500V 1min


Insultlation:

Max. 100M Ohm


Contact: 

Max. 5m Ohm



PDF
HPH

HPH

AC/DC125V 20A

Alarm Contact:

AC 1250~3750V 1min.


 Other: 

AC 2500V 1min

 

Insultlation:

Max. 100M Ohm


Contact: 

Max. 5m Ohm



PDF

  

P/PL/SP             P4L/PL4L/SP4L        P4H            UP/UPK 

Photo
Series Type
Rated Voltage
Rated Current
Breaking
Capacity
Approvals
Catalog
P4,PL4,P3,PL3
P4


AC220V
DC250V
0.3A - 5A AC220V 2500A
DC250V 1500A
 
(Nippon Telegraph
and Telephone
Corporation) 

except P435

PDF

PL4

 

AC/DC125V

7.5A - 10A AC125V 2500A
DC125V 1500A

 

AC/DC125V

15A AC/DC125V 1000A
P4,PL4(BSS) P4 (BSS)
PL4 (BSS)


AC220V
DC250V
0.2A - 3.5A -
(Japan Broadcasting
Corporation)

 


PDF

AC/DC100V
5A

-
SP4,SP3 SP4

(Time-lag)

AC220V
DC250V
0.1A - 2A AC220V 2500A
DC250V 1500A


except SP450

PDF
AC220V
DC250V
3A - 3.5A AC220V 1500A
DC250V 300A
AC/DC125V
5A

AC/DC125V 1000A
P4L,PL4L P4L
PL4L


AC/DC125V 0.4A - 7.5A
AC125V 10000A
DC125V 1500A



PDF
10A - 15A AC/DC125V 100A
AC/DC60V 200A
P4H P4H

AC/DC250V 0.4A - 5A
AC/DC250V 1500A
AC125V 10000A





PDF
7.5A - 10A
AC/DC250V 200A
AC125V 10000A

SP4L SP4L

(Time-lag)

AC/DC250V 0.3A - 3.5A AC/DC250V 200A
AC125V 10000A

PDF

  

Photo
Series Type
 
Suitable
Fuses
Wiring
Connection
mounting
Approvals
Catalog
P4-1S
P4-1S
PL4-1S
Brown
 
P4
PL4


P4(BSS)
PL4(BSS)


P4L
PL4L


P4H


SP4


SP4L
Soldering
Panel screw-in



P4-2S
P4-2S
PL4-2S
 
Panel clip-on



P4-1SB
P4-1SB

 
Panel screw-in

(Alarm circuit is closed

if the fuse is not mounted)

-
P4-2SB
P4-2SB

 
Panel clip-on

(Alarm circuit is closed

if the fuse is not mounted)



P4-1C
P4-1C
P4-1C(YR)
 
Receptacle
terminal
Panel screw-in
P4-2C
P4-2C
P4-2C(YR)
 
Panel clip-on
P4-1P
P4-1P
P4-1P(YR)
 
PCB
PCB screw-in


P4-1PB
P4-1PB

 
PCB screw-in

(Alarm circuit is closed

if the fuse is not mounted)

P4-4S
P4-4S

-
Surface
connection
DIN rail mountable

DS-401A
DS-401A


 
Distribution type

(Common alarm circuit)
screw
-
 
 
 
 

 
 
 
 
HP fuses and fuseholders                              GP fuses and fuseholders
HP                                           

Alarm indicator fuses of the normal blow, with rated voltage of AC/DC250V.

Thin, compact(8mm thick) and high breaking performance of AC/DC250V and 1500A (rated current of 5A or less).

 Alarm indicator fuses of the normal blow, with rated voltage of AC/DC250V.

Large capacity up to 15A is covered.High breaking performance exceeding AC/DC250V and 750A.
The circuit between the fuse and alarm indicator circuits meets the reinforced insulation standards specified under IEC 60950.

 

MP/SDP fuses and fuseholders                       EP fuses and fuseholders

MP/SMP                                         EP

Compact alarm indicator fuses with rated voltage of AC/DC125V.

MP and SDP fuses of the fast blow and time lag types respectively are available. 

EP fuses and fuseholders

Alarm indicator fuses of the normal blow, with rated voltage of AC/DC125V.

Thin, compact(8mm thick) and large-capacity fuses with 20A maximum rated current.

P/PL/SP fuses and fuseholders                                       P4L/PL4L/SP4L fuses

P/PL/SP                                                  P4L/PL4L/SP4L

 

P4H fuses                                                                     UP/UPK fuses and fuseholders

P4H                                                  UP/UPK       

Basic product of alarm indicator fuse with more than 40 years' expert experience in the domain of telecommunication equipment.
Products conforming to BSS (specifications of NHK : Japan Broadcasting Corporation) are also available.
Please also refer to Daito catalog for rated voltage and other detailed specification. 

P4, PL4 and SP4 fuses with UL approval (Recognition).

 

P4L and PL4L fuses of the normal blow type and SP4L fuse of the time lag type are available.

Alarm indicator fuses of the normal blow, with rated voltage of AC/DC250V.
P4 fuses of the non-emission type, featuring no arc gas blowoff when blown.
High breaking performance of AC/DC250V and 1500A (rated current of 5A or less). 

Alarm indicator fuses of the normal blow, with rated voltage of AC250V/DC125V.
Large capacity up to maximum rated current of 70A (UP700K) is covered with external dimension of 32x25x23mm (excluding terminals).
High breaking performance exceeding AC250V/1500A and DC125V/1000A.

 

日本大東保險絲為一高信賴性與高性能之裝置 因其支獨特性能所以被廣泛的應用於電信網路通訊,工業與機械控制或核能與石化電廠等應用範圍.

大東警報型保險絲特點:

1. 高信賴性

2. 插拔式設計易於維修替換

3. 內部警報接點可提供外部設備快速偵測告警故障事件

4. 獨特之專利結構可讓使用者立即目視判斷保險絲是否熔斷 

5. 保險絲座可同時適用多種不同規格之保險絲